Code: 005
Description: Service Call Op Panel
Remedy: 1 Is the operator panel cable properly connected to the op panel? Go to step 2. Properly connect the cable to the op panel. 2 Is the op panel cable properly connected to the RIP board connector J-PNL1? Go to step 3. Properly connect the cable to J-PNL1. 3 Check the op panel cable continuity. Is there continuity? Go to step 4. Replace the flatbed unit. See “Flatbed assembly removal”. 4 Check Voltages on J-PNL1, located on the RIP card. Pin 1 voltage should measure 5V. Is it correct? Replace the operator panel. See “Operator panel removal”. Replace the system board. See “System board removal”.