Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 845.xx — Lexmark X543

Code: 845.xx

Description: Scanner failure CCD failure 845 Front scan module cable failure or SCC card failure CCD channel failure. Check each channel (mono, R, G, B) for identical values indicating bad cable and/or SCC card. Excessive noise test for the dark data indicating some sort of CCD or analog electronics issue on that channel or channels. 845.01 Rear scan module cable failure or SCC card failure CCD channel failure. Check each channel(mono, R, G, B) for identical values indicating bad cable and/or SCC card. Excessive noise test for the dark data indicating some sort of CCD or analog electronics issue on that channel or channels. 845.02 Cable/SCC failure. Front scan module connector or cable failure. 845.03 Cable/SCC failure Rear scan module connector or cable failure. 845.04 Cable failure The connector cable is defective.
Remedy: 1 Restart the device, and retry the scan / copy job. Repeat this step with a few copy jobs. Does the error reoccur? Go to step 2. No issue. 2 Is the CCD ribbon cable properly connected to JCCD1 on the RIP board? Go to step 3. Properly connect the ribbon cable to JCCD1. 3 Replace the flatbed unit. See “Flatbed removal”. Did this resolve the issue? Problem resolved. Replace the RIP board. See “RIP board removal”.

← Xem tất cả mã lỗi Lexmark X543