Mã lỗi 122.xx — Lexmark X544dw

Code: 122.xx

Description: Service Fuser Error Fuser error 122.01 Service Fuser Error EWC error—Attempting to print with estimated power at or below minimum power. 122.02 Service Fuser Error Fuser over temperature. 122.03 Service Fuser Error Fuser open thermistor check failed. 122.04 Service Fuser Error EWC Error—Did not reach EWC start temperature in time. 122.05 Service Fuser Error EWC Error—Did not change temperature within expected time. 122.06 Service Fuser Error EWC Error—Did not reach EWC stop temperature in time. 122.10 Service Fuser Error Fuser failed to warm up. 122.11 Service Fuser Error Fuser under temperature error while in standby. 122.12 Service Fuser Error Fuser under temperature error while printing. 122.13 Service Fuser Error Fuser open thermistor check failed for second thermistor. 122.14 Service Fuser Error Fuser shorted thermistor check failed for hot roll thermistor. 122.15 Service Fuser Error Fuser started thermistor check failed for second thermistor. 122.16 Service Fuser Error EWC Error—Estimated power is at or above maximum power. 122.17 Service Fuser Error Total failure to close fuser nip.
Remedy: 1 Some low-voltage power supply FRUs have a voltage selector switch. If it does, the switch needs to be set to the correct voltage for your area. Has the LVPS been changed? Check the switch on the side of the LVPS to verify the correct voltage is set. Go to step 2. 2 Turn the printer off, and remove the rear shield. See “Rear shield removal”. Check the cable at JFUSES1 for proper connection to the RIP board, the cable for pinch points, and the cable or connector for any other damage. Is the cable damaged? Replace the fuser cable. Go to step 3. 3 Check the connector JLVPS1 for proper connection to the RIP board, the cable for pinch points, and the cable or connector for any other damage. Is the cable damaged? Repair or replace the LVPS cable. See “Low-voltage power supply (LVPS) assembly removal”. Go to step 4. 4 Check the power cable on the left side of the fuser and the thermistor cables and connections on the right side of the fuser. Are the cables or connectors damaged? Repair the cables. If the cables cannot be repaired, replaced the fuser. See “Fuser assembly removal”. Go to step 5. 5 Disconnect the cable at JFUSES1 on the RIP board, and check the following voltages: Are the values approximately correct? Go to step 6. Replace the RIP board. See “RIP board removal”. 6 Replace the fuser. See “Fuser assembly removal”. Does the error clear? Problem resolved. Replace the RIP board. See “RIP board removal”.

← Xem tất cả mã lỗi Lexmark X544dw

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie