Code: 841
Description: Image pipeline Image pipeline ASIC.
Remedy: 1 Restart the device, and retry the scan / copy job. Repeat this step with a few copy jobs. Does the error reoccur? Go to step 2. No issue. 2 Is the CCD ribbon cable properly connected to JCCD1 on the RIP board? Go to step 3. Properly connect the ribbon cable to JCCD1. 3 Replace the flatbed unit. See “Flatbed removal”. Did this resolve the issue? Problem resolved. Replace the RIP board. See “RIP board removal”.
Flatbed home position service check
1 POR the printer. Does the CCD move and return to the home position? Problem solved. Go to step 2. 2 Perform the home position sensor test. Go to “SCANNER TESTS”. Is the sensor working properly? Go to step 3. Go to step 5. 3 Check JFBM1 on the controller for proper connection. Is it connected properly? Go to step 4. Properly connect the cable. 4 Check pin 1 in JFBM1 for voltage. The voltage is only present when a flatbed copy job is running. The voltage should measure +24 V ac. Is voltage present? Go to step 5. Replace the RIP board. Go to “RIP board removal”. 5 Ensure that the home position cable (JHS1) is connected. Is the cable connected? Go to step 6. Properly connect the cable. 6 Check pin 1 in JHS1 for voltage. The voltage should measure +5 V dc. pin 2 should be GND. Is voltage present and is it correct? Replace the flatbed unit. See “Flatbed removal”. Replace the RIP board. Go to “RIP board removal”.
Flatbed home position service check
1 POR the printer. Does the CCD move and return to the home position? Problem solved. Go to step 2. 2 Perform the home position sensor test. Go to “SCANNER TESTS”. Is the sensor working properly? Go to step 3. Go to step 5. 3 Check JFBM1 on the controller for proper connection. Is it connected properly? Go to step 4. Properly connect the cable. 4 Check pin 1 in JFBM1 for voltage. The voltage is only present when a flatbed copy job is running. The voltage should measure +24 V ac. Is voltage present? Go to step 5. Replace the RIP board. Go to “RIP board removal”. 5 Ensure that the home position cable (JHS1) is connected. Is the cable connected? Go to step 6. Properly connect the cable. 6 Check pin 1 in JHS1 for voltage. The voltage should measure +5 V dc. pin 2 should be GND. Is voltage present and is it correct? Replace the flatbed unit. See “Flatbed removal”. Replace the RIP board. Go to “RIP board removal”.