Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 077-343 — Lexmark X560

Code: 077-343

Display: Motor Error Error 077-343 Restart Printer
Description: <IOT Motor Failure> A feed motor failure is detected.
Remedy: 1 Check the rotation of the registration roll rubber with a finger. Does the rubber on the registration roll rotate correctly? Go to step 2. Replace the feeder assembly. 2 Check the P/J25 and P/J251 connectors between the controller board and the feed drive assembly. Are the connections secure? Go to step 3. Reconnect the connectors P/J25 and P/J251. Then go to step 3. 3 Check the PH Motor by performing the PH Motor Test: 1. In Service Mode, select Printer Diag, and press OK. 2. Select Engine Diag, and press OK. 3. Select Motor Tests, and press OK. 4. Select PH Motor. 5. Open the front cover. 6. Press OK. 7. Select a speed to test, and press OK to start the test. For example, select PH Motor(Full2). 8. During the Test, close the front cover. You will hear the motor run if it is functional Does the PH motor function correctly? Replace the controller board. See “Controller board removal”. Go to step 4. 4 Is the feed drive assembly installed correctly? Go to step 5. Reinstall the feed drive assembly. See “Feed drive assembly removal”. Then go to step 5. 5 Does the error still occur when the power is turned on? Go to “Feed drive assembly service check”. Problem resolved.