Mã lỗi 922.02...922.97 — Lexmark X644

Code: 922.02...922.97

Description: Hot roll took too long to reach the beginning lamp detection temperature. • Low wattage or incorrect lamp. • Bad thermistor, circuit, or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage.
Remedy: 1 Fuser lamp Remove the fuser assembly and check to make sure the correct fuser lamp has been installed. If the correct lamp has been installed, go to step 2. Note: If the fuser lamp is replaced, allow the fuser assembly to cool or a 925.xx error code could be displayed. 2 AC line voltage CAUTION: When taking measurements for AC power, observe all safety precautions. Check the AC line voltage to make sure it is within operating specification. If incorrect, inform the customer; if correct, go to step 3. 3 LVPS CAUTION: When taking measurements for AC power, observe all safety precautions. Unplug the AC line cord from the printer and pull the LVPS out far enough to access CN1 on the LVPS board (see “Low voltage power supply removal”). Disconnect the LVPS to fuser AC cable, plug in the line cord, turn the printer on and measure the voltage between CN1-1 and CN1-3 on the connector (see the connector locations at “Low voltage power supply”). If incorrect, replace the LVPS assembly (see “Low voltage power supply removal”); if correct, go to step 4. 4 LVPS LVPS fuser AC cable CAUTION: When taking measurements for AC power, observe all safety precautions. Disconnect the AC line cord from the printer. Disconnect the LVPS to fuser cable from the fuser to fuser lamp cable. Plug the AC line cord into the printer and check the AC line voltage between the pins on the fuser end of the LVPS to fuser AC cable. If the voltage is correct, unplug the AC power cord from the LVPS cable and pull the LVPS out far enough to be able to check the voltage between CN-1 and CN-3 on the LVPS board. Plug in the power cord, turn the printer on and check the voltage. If correct, replace the LVPS to fuser AC cable; if incorrect, replace the LVPS assembly. See “Low voltage power supply removal”. Note: If the fuses in the LVPS are blown, the LVPS assembly must be replaced. 5 Fuser top cover assembly (thermistor, thermistor cable) Fuser to system board DC cable Check to make sure that the thermistor is installed correctly to J5 on the fuser control card. If installed correctly check the cable for any signs of damage. If any problems are found, replace the fuser top cover assembly.“Fuser narrow media sensor removal”. If no problem is found, check the fuser to system board DC cable for correct installation at J1 on the fuser control card. If no problem is found, check the fuser to system board cable for correct installation at J10 on the system board. If no problem is found, go to step 6. 6 Fuser assembly If no problem is found up to this point, then replace the following in the order shown: • Fuser assembly. See “Fuser assembly removal”. • System board assembly. See “System board and inner shield removal —models X644e/X646e”. • LVPS. See “Low voltage power supply removal”.

← Xem tất cả mã lỗi Lexmark X644

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie