Description: 930.00 Incorrect printhead or intermittent Hsync A non supported printhead is installed. Hsync signal is intermittent or noisy. Printhead ID resistor circuit is not to spec. 931.00 No first laser H sync The hsync signal is missing or not at the correct voltage. 932.00 Printhead lost laser H syncs. The hsync signal is missing or not at the correct voltage. 933.00 Polygon mirror motor locked. No first laser H sync received. The hsync signal is missing or not at the correct voltage.