Description: POST Error Fuser bubble sensor is not connected.
Remedy: 1 Is the bubble sensor flag (A) damaged? Replace the fuser. See “Fuser assembly removal”. Go to step 2. 2 1. Remove the rear frame cover. See “Rear frame cover removal”. 2. Check the fuser DC cable in connector JFUSER1 for proper connection to the system board, pinch points, and any other damage to the cable or connector. Is the cable damaged? Replace the fuser DC cable. See “Fuser DC cable removal”. Note: Make sure to verify if the new cable is working properly first. Route the cables properly only when you have verified that the cables are working properly. Go to step 3. 3 Place a voltmeter between fuser DC autoconnect pin 3, and ground (pin 6). Does the meter read +5 V dc? Go to step 5. Go to step 4. 4 Place a voltmeter between the JFUSER1, pin 3 and ground (pin 6). Does the voltage drop to +5 V dc? Replace the system board. See “System board removal”. Go to step 5. 5 1. Replace the fuser. 2. Enter Diagnostics mode (press and hold buttons 3 and 6, turn on the MFP, and release the buttons when the progress bar displays.) 3. Touch SENSOR TESTS. 4. Touch Dynamic Sensors. 5. Touch Bubble. 6. Open the front access door and the top access cover. 7. Activate the bubble sensor flag (A). Did the bubble sensor change from Open to Closed on the touchscreen? Problem resolved. Replace the system board. See “System board removal”.