Code: 144.09 ... 144.27
Description: Motor Error EP Drive assembly cartridge 2 (middle) motor has failed.
Remedy: 1 1. Turn the printer off. 2. Remove the rear frame cover. See “Rear frame cover removal”. 3. Remove the right cover. See “Right cover removal”. 4. Check the cables in connector JCARTP2and JCARTS2 (cartridge motor 2/3 cable) for proper connection to the system board, for cable pinch points, and for any other damage to the cable or connector. Is the cable damaged? Replace cartridge motor 2/ 3 cable. See “Cartridge motor 2/3 cable removal”. Go to step 2. 2 1. Remove the right cover. See “Right cover removal”. 2. Check the cartridge motor 2/3 cable for proper connection to the EP drive assembly, pinch points for the cable, or damage to the cable or connector (A). Is either cable damaged? Replace the cartridge motor 2/3 cable. See “Cartridge motor 2/3 cable removal”. Go to step 3. 3 Measure the continuity across all of the fuses on the system board. Are any of the fuses blown? Replace the system board. See “System board removal”. Go to step 4. 4 1. Disconnect the cartridge motor 2/3 cable on the motor and on the system board. 2. Connect a new motor 1/fuser motor cable on the motor and on the system board. 3. Run diagnostics motor check. Bring the printer up in Diagnostics Menu (turn off the printer, press and hold buttons 3 and 6, then turn on the printer). 4. Select MOTOR TESTS. Did the motor run? Replace the cartridge motor 2/3 cable. See “Cartridge motor 2/3 cable removal”. Go to step 5. 5 1. Return the old cartridge motor 2/3 motor cable. 1. Disconnect the motor drive cable from the EP drive assembly and connect it to the motor on a new EP drive assembly. Note: Do not install the new EP drive assembly yet. 2. Enter Diagnostics mode (press and hold buttons 3 and 6, turn on the MFP, and release the buttons when the progress bar displays). 3. Touch MOTOR TESTS. Did the motor run? Replace the EP drive assembly. See “Electrophotographic (EP) drive assembly removal”. Replace the system board. See “System board removal”.