Mã lỗi 925.02, 925.04, 925.06 — Lexmark X748de

Code: 925.02, 925.04, 925.06

Description: 925.02 Blower Error Blower has stalled. 925.04 Blower Error Blower has stalled. 925.06 Blower Error Blower has stalled.
Remedy: 1 1. Turn the printer off. 2. Remove the rear frame cover. See “Rear frame cover removal”. 3. Check the cable in connector JBLW1 for proper connection to the system board, for pinch points, and any other damage to the cable or connector, and reseat the cable. Did the error clear? Problem resolved. Go to step 2. 2 Measure the continuity across all of the fuses on the system board. Are any of the fuses blown? Replace the system board. See “System board removal”. Go to step 3. 3 1. Replace the cartridge cooling fan. See “Cartridge cooling fan removal”. 2. Turn the multifunction printer off, and turn the MFP on (perform a POR). Note: After installing the new fan, a print test is required to verify operation. Print one page every 30 seconds for 20 minutes to test the highest fan speed. Do not test unless the fan is installed in the machine. Did the error clear? Problem resolved. Replace the system board. See “System board removal”.