Mã lỗi 120.00 ... 120.21 — Lexmark X748dte

Code: 120.00 ... 120.21

Description: Fuser Error An error has occurred in the fuser.
Remedy: 1 Check the input voltage switch on the back of the low-voltage power supply (LVPS). Note: Some LVPS FRUs do not have a switch, and are switch automatically. If your FRU does not have this switch, go to step 2. Is the voltage level (115 V/230 V) properly set? Go to step 2. Set the switch for the proper country voltage. 2 1. Remove the fuser. See “Fuser assembly removal”. 2. Check the fuser AC autoconnect cable for damage, check the other end of the cable for damaged pins. 3. Check the fuser DC autoconnect cable for damaged pins. Are the connectors damaged? Replace the appropriate cable (either the fuser AC or the fuser DC cable). See “Fuser AC cable removal” or “Fuser DC cable removal”. Go to step 3 3 Replace the fuser. See “Fuser assembly removal”. Did the error clear? Problem resolved. Go to step 4. 4 1. Remove the rear frame cover. See “Rear frame cover removal”. 2. Check the cable in connector JFUSER1 (fuser DC cable) for proper connection to the system board. the cable for pinch points, and the cable or connector for any other damage. Is the cable damaged? Replace the fuser DC cable. See “Fuser DC cable removal”. Go to step 5. 5 Check the cable in connector JLVPS2 for proper connection to the system board, the cable for pinch points, and the cable or connector for any other damage. Is the cable damaged? Replace the LVPS. See “Low-voltage power supply (LVPS) removal”. Go to step 6. 6 Measure the continuity across all of the fuses on the system board. Are any of the fuses blown? Replace the system board. See “System board removal”. Go to step 7. 7 Check for the following continuity between the DC autoconnect and JFUSER1 on the system board. Is continuity present? Go to step 8. Replace the fuser DC cable. See “Fuser DC cable removal”. 8 Check for continuity between the following pins of the AC autoconnect and the pins of the connector that connects to the LVPS. Is continuity present? Replace the system board. See “System board removal”. Replace the fuser AC cable. See “Fuser AC cable removal”.

← Xem tất cả mã lỗi Lexmark X748dte

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie