Mã lỗi 294.02 — Lexmark X850e

Code: 294.02

Description: Scanner jam Remove all originals from the scanner. Sensor (ADF pre-registration) off jam on inverting After the ADF registration motor turned on at Invert, the sensor (ADF pre-registration) did not turn off within the specified time.
Remedy: 1 Check the original document condition. Is the original document free of paper clips and staples as well as damage such as creases, tears, holes, or excessive wear? Go to step 2. Remove damaged original document and replace with a new undamaged original document. Perform a ADF test. If the problem remains, go to step 2. 2 Check the ADF rolls for wear. Is the ADF feed/pick roll assembly or the ADF separation roll guide assembly free of excess wear? Go to step 3. Clean or replace the ADF feed/pick roll assembly or the ADF separation roll guide assembly. Go to “ADF feed/ pick roll assembly removal” or “ADF separation roll guide assembly”. 3 Check the media path for contaminates. Is the media path free of excess media dust and foreign objects such as paper clips and staples? Go to step 4. Remove all contaminates from the media path. 4 Check the sensor (sheet through) for operation. Perform the sensor (sheet through) test. Open the ADF left cover assembly. Remove the ADF rear cover. Go to “ADF rear cover removal”. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch Sheet through. Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 6. Go to step 5. 5 Check the sensor (sheet through) for connection. Is the above sensor connected properly? Replace the sensor (sheet through). Go to “Sensor (sheet through) removal”. Replace the connection. 6 Check the sensor (ADF pre registration) for operation. Perform the sensor (ADF pre registration) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF pre registration. Operate the actuator of the sensor (ADF pre registration). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 8. Go to step 7. 7 Check the sensor (ADF pre-registration) for connection. Is the above sensor connected properly? Replace the sensor (ADF preregistration). Go to “Sensor (ADF preregistration)”. Replace the connection. 8 Check the feed drive motor for correct operation. Perform the feed drive motor test. Open the ADF left cover assembly. Remove the ADF rear cover. Go to “ADF rear cover removal”. 1. Enter the Diagnostics Menu. 2. Touch MOTOR TESTS. 3. Touch Scanner Motor Tests. 4. Touch ADF feed drv mtr. Does the feed drive motor rotate properly? Go to step 10. Go to step 9. 9 Check the feed drive motor for connection. Is the above sensor connected properly? Replace the ADF feed drive motor assembly. Go to “ADF feed drive motor assembly removal”. Replace the connection. 10 Check the inverter solenoid assembly for operation. Perform the inverter solenoid test. Open the ADF left cover assembly. Remove the ADF front cover assembly. Go to “ADF front cover assembly removal”. Close the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch MOTOR TESTS. 3. Touch Scanner Motor Tests. 4. Touch Inverter solenoid. Does the inverter solenoid assembly operate properly? Go to step 12. Go to step 11. 11 Check the inverter solenoid assembly for connection. Is the above motor connected properly? Replace the inverter solenoid assembly. Go to “Inverter solenoid assembly removal”. Replace the connection. 12 Check the registration motor (forward or reverse) test. Perform the registration motor test. Open the ADF left cover assembly. Remove the ADF rear cover. Go to “ADF rear cover removal”. 1. Enter the Diagnostics Menu. 2. Touch MOTOR TESTS. 3. Touch Scanner Motor Tests. 4. Touch ADF registration drv mtr. 5. Touch Forward or reverse. Does the ADF registration motor operate properly? Go to step 14. Go to step 13. 13 Check the ADF registration motor for connection. Is the above motor connected properly? Replace the ADF registration motor. Go to “ADF registration motor removal”. Replace the connection. 14 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the ADF controller card assembly. Go to “ADF controller card assembly removal”. Go to step 15. 15 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the RIP card assembly. Go to “RIP card assembly removal”. Problem solved.

← Xem tất cả mã lỗi Lexmark X850e

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie