Code: 295.00
Description: Scanner jam Remove all originals from the scanner. Size mismatch Jam (Mix-size) In Mixed Size Originals, it was detected that the Fast Scan Direction size was different from the width of the document guide.
Remedy: 1 Check the document tray media guide position. Are the document tray media guides set correctly? Go to step 2. Adjust the document tray media guides to the proper position. 2 Check the sensor (ADF width APS 1) for operation. Perform the sensor (ADF width APS 1) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF width APS 1. Operate the actuator of the sensor (ADF width APS 1). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 2. Go to step 3. 3 Check the sensor (ADF width APS 1) for connection. Is the above sensor connected properly? Replace the sensor (ADF width APS 1). Go to “Sensor (ADF width APS 1)”. Replace the connection. 4 Check the sensor (ADF width APS 2) for operation. Perform the sensor (ADF width APS 2) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF width APS 2. Operate the actuator of the sensor (ADF width APS 2). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 6. Go to step 5. 5 Check the sensor (ADF width APS 2) for connection. Is the above sensor connected properly? Replace the sensor (ADF width APS 2). Go to “Sensor (ADF width APS 2)”. Replace the connection. 6 Check the sensor (ADF width APS 3) for operation. Perform the sensor (ADF width APS 3) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF width APS 3. Operate the actuator of the sensor (ADF width APS 3). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 8. Go to step 7. 7 Check the sensor (ADF width APS 3) for connection. Is the above sensor connected properly? Replace the sensor (ADF width APS 3). Go to “Sensor (ADF width APS 3)”. Replace the connection. 8 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the ADF controller card assembly. Go to “ADF controller card assembly removal”. Go to step 9. 9 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the RIP card assembly. Go to “RIP card assembly removal”. Problem solved.