Mã lỗi 242.01 — Lexmark X852

Code: 242.01

Description: Paper jam Check area B, tray 2 Sensor (tray 2 feed-out) on jam (tray 2 feed) The sensor (tray 2 feed-out) is not turned on within the specified time after the sensor (pre-feed) media feed unit 2 is turned on.
Remedy: 1 Check the media condition. Is the media in the tray crumpled or damaged? Replace the media with new media; ensure it is dry. Go to step 2. 2 Check the media size setup. Does the media size in use match the size set for tray 2? Go to step 2. Replace the media, or change the media size setup. 3 Check the rolls for tray 2. Pull out the tray 2, and check it. Open the printer left lower door assembly, and visually check it. Are the feed roll, separation roll, and pick roll free of excess wear and contamination? Go to step 4. Clean or replace the feed roll, separation roll, and pick roll. Go to “Feed roll removal”, “Separation roll removal”, and “Pick roll removal”. 4 Check the media position. Does the media touch the sensor (tray 2 feed-out) or the tray 2 media feed unit? Remove the media. Go to step 5. 5 Check the sensor (tray 2 feed-out) for proper operation. 1. Enter the Diagnostics Menu. 2. Touch INPUT TRAY TESTS. 3. Touch Sensor test. 4. Touch Tray 2. 5. Touch Media out. Open the printer left lower door assembly and check it. Does the display on the operator panel change every time a white piece of paper is placed over the sensing area? Go to step 7. Go to step 6. 6 Check the sensor (tray 2 feed-out) connection. Is the sensor (tray 2 feed-out) properly connected? Replace the sensor (tray 2 feed-out). Go to “Sensor (tray 2 feed-out) removal”. Replace the connection. 7 Check the sensor (pre-feed), in tray 2, for proper operation. 1. Enter the Diagnostics Menu. 2. Touch INPUT TRAY TESTS. 3. Touch Sensor test. 4. Touch Tray 2. 5. Touch Pre-feed. Remove the media tray assembly and check it. Does the display on the operator panel change every time a white piece of paper is placed over the sensing area? Ensure the media feed unit front guide is installed properly. Go to step 9. Replace the sensor (pre-feed). 8 Check the sensor (pre-feed) connection. Is the sensor (pre-feed) properly connected? Replace the sensor (pre-feed). Replace the connection. 9 Check the MPF/transport drive motor. Perform the MPF/transport drive motor test. Open the ADF left cover assembly. Remove the rear motor cover. Go to “Rear motor cover removal”. 1. Enter the Diagnostics Menu. 2. Touch MOTOR TESTS. 3. Touch Printer Motor Tests. 4. Touch MPF/Transport mtr. Does the MPF/transport motor operate properly? Go to step 11. Go to step 10. 10 Check the MPF/transport drive motor for connection. Is the above motor connected properly? Replace the MPF/ transport drive motor. Go to “MPF/ transport drive motor assembly removal”. Replace the connection. 11 Perform a print test. Does the error continue? Replace the printer engine card assembly. Go to “Printer engine card assembly removal”. Problem solved.

← Xem tất cả mã lỗi Lexmark X852

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie