Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 846.13 — Lexmark X852e

Code: 846.13

Description: Service scanner error Switch (platen interlock) open The system detected that the switch (platen interlock) is open.
Remedy: 1 Check the ADF for opening and closing. Does the ADF lay completely flush on the scanner unit when it is in its closed position? Go to step 2. Inspect and adjust the ADF left hinge and right hinge as required. 2 Check the sensor (ADF angle) for proper installation. Is the sensor (ADF angle) installed correctly? Go to step 3. Reinstall the sensor (ADF angle). 3 Check the sensor (ADF angle) for operation. Perform the sensor (ADF angle) test. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF angle. Open and close the ADF unit assembly. Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 5. Go to step 4. 4 Check the sensor (ADF angle) for connection. Is the above sensor connected properly? Replace the sensor (ADF angle). Go to “Sensor (ADF angle) removal”. Replace the connection. 5 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the scanner controller card assembly. Go to “Scanner controller card assembly removal”. Go to step 6.

← Xem tất cả mã lỗi Lexmark X852e

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie