Description: Service fuser error Over heat temperature failure The control thermistor detects a temperature higher than the specified value. The lamp change thermistor detects a temperature higher than the specified value.
Remedy: 1 Check the fuser unit assembly for proper installation. Open the printer left door assembly, and check it. Is the fuser unit assembly installed properly? Go to step 2. Install the fuser unit assembly properly. 2 Check the fuser unit assembly for proper connection. Go to step 3. Replace the connection. 3 Check the connection between the LVPS card assembly P525 and the printer engine card assembly P401. Are the cards connected properly? Replace the fuser unit assembly. Replace the connection. 4 Perform a print test. Does the error continue? Replace the printer engine card assembly. Go to “Printer engine card assembly removal”. Problem solved.