Mã lỗi 290.02 — Lexmark X860

Code: 290.02

Description: Scanner jam Remove all originals from the scanner. Sensor (ADF pre-registration) on jam ADF simplex side 1 After the Pre Feed operation started for the first sheet, the feed drive motor turned on (CW)) in Duplex or Simplex mode, the sensor (ADF preregistration) did not turn on within the specified time. After the Pre Feed operation started for the second sheet, the feed drive motor turned on (CW)) in Duplex mode, the sensor (ADF pre-registration) did not turn on within the specified time.
Remedy: 1 Check the original document condition. Is the original document free of paper clips and staples as well as damage such as creases, tears, holes, or excessive wear? Go to step 2. Remove damaged original document, and replace with a new undamaged original document. Perform a ADF test. If the problem remains, go to step 2. 2 Open the ADF left cover assembly and inspect the document set actuator as shown in the graphic below. Is the document set actuator flag flat as shown in the graphic below? Replace the document set actuator. Note: To receive the new rounded flag actuator, order 40X2283. Go to “Document set actuator removal”. If problem remains, go to step 3. 3 Check the ADF rolls for wear. Is the ADF feed/pick roll assembly or the ADF separation roll guide assembly free of excess wear? Go to step 4. Clean or replace the ADF feed/pick roll assembly or the ADF separation roll guide assembly. Go to “ADF feed/ pick roll assembly removal” or “ADF separation roll guide assembly”. 4 Check the media path for contaminates. Is the media path free of excess media dust and foreign objects such as paper clips and staples? Go to step 5. Remove all contaminates from the media path. 5 Check the sensor (ADF pre registration) for operation. Perform the sensor (ADF pre registration) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF pre registration. Operate the actuator of the sensor (ADF pre registration). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 7. Go to step 6. 6 Check the sensor (ADF pre-registration) for connection. Is the above sensor connected properly? Replace the sensor (ADF preregistration). Go to “Sensor (ADF preregistration)”. Replace the connection. 7 Check the feed drive motor for correct operation. Perform the feed drive motor test. Open the ADF left cover assembly. Remove the ADF rear cover. Go to “ADF rear cover removal”. 1. Enter the Diagnostics Menu. 2. Touch MOTOR TESTS. 3. Touch Scanner Motor Tests. 4. Touch ADF feed drv mtr. Does the feed drive motor rotate properly? Go to step 9. Go to step 8. 8 Check the feed drive motor for connection. Is the above motor connected properly? Replace the ADF feed drive motor assembly. Go to “ADF feed drive motor assembly removal”. Replace the connection. 9 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the ADF controller card assembly. Go to “ADF controller card assembly removal”. Go to step 10. 10 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the RIP card assembly. Go to “RIP card assembly removal”. Problem solved.

← Xem tất cả mã lỗi Lexmark X860

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie