Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 291.03 — Lexmark X864

Code: 291.03

Description: Scanner jam Remove all originals from the scanner. Sensor (ADF inverter) off jam After the sensor (ADF registration) turned off during the Read operation of the last document, the sensor (ADF inverter) did not turn off within the specified time. (Simplex mode) After the ADF registration motor turned on (CCW) during the Read operation, the sensor (ADF inverter) did not turn off within the specified time. (Simplex mode) After the sensor (ADF registration) turned off during the Read operation, the sensor (ADF inverter) did not turn off within the specified time. (Duplex mode)
Remedy: 1 Check the original document condition. Is the original document free of paper clips and staples as well as damage such as creases, tears, holes, or excessive wear? Go to step 2. Remove damaged original document and replace with a new undamaged original document. Perform a ADF test. If the problem remains, go to step 2. 2 Check the ADF rolls for wear. Is the ADF feed/pick roll assembly or the ADF separation roll guide assembly free of excess wear? Go to step 3. Clean or replace the ADF feed/pick roll assembly or the ADF separation roll guide assembly. Go to “ADF feed/ pick roll assembly removal” or “ADF separation roll guide assembly”. 3 Check the media path for contaminates. Is the media path free of excess media dust and foreign objects such as paper clips and staples? Go to step 4. Remove all contaminates from the media path. 4 Check the sensor (ADF inverter) for operation. Perform the sensor (ADF inverter) test. Open the ADF left cover assembly. Remove the ADF separation roll guide assembly. Go to “ADF separation roll guide assembly”. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF inverter. Insert a sheet of paper into the ADF paper path entrance. Manually rotate the ADF exit roll assembly by hand to feed the sheet through the ADF to operate the actuator of the sensor (ADF inverter). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 6. Go to step 5. 5 Check the sensor (ADF inverter) for connection. Is the above sensor connected properly? Replace the sensor (ADF inverter). Go to “Sensor (ADF inverter)”. Replace the connection. 6 Check the sensor (ADF registration) for operation. Perform the sensor (ADF registration) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF registration. Place a piece of white paper into the ADF media entrance and over the sensor (ADF registration). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 8. Go to step 7. 7 Check the sensor (ADF registration) for connection. Is the above sensor connected properly? Replace the sensor (ADF registration). Go to “Sensor (ADF registration)”. Replace the connection. 8 Check the inverter gate condition. Is the inverter gate free of damage and warpage; and does it move smoothly? Go to step 9. Replace the inverter gate. Go to “Inverter gate removal”. 9 Check the registration motor (forward or reverse) test. Perform the registration motor test. Open the ADF left cover assembly. Remove the ADF rear cover. Go to “ADF rear cover removal”. 1. Enter the Diagnostics Menu. 2. Touch MOTOR TESTS. 3. Touch Scanner Motor Tests. 4. Touch ADF registration drv mtr. 5. Touch Forward or reverse. Does the ADF registration motor operate properly? Go to step 11. Go to step 10. 10 Check the ADF registration motor for connection. Is the above motor connected properly? Replace the ADF registration motor. Go to “ADF registration motor removal”. Replace the connection. 11 Check the inverter solenoid assembly for operation. Perform the inverter solenoid test. Open the ADF left cover assembly. Remove the ADF front cover assembly. Go to “ADF front cover assembly removal”. Close the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch MOTOR TESTS. 3. Touch Scanner Motor Tests. 4. Touch Inverter solenoid. Does the inverter solenoid assembly operate properly? Go to step 13. Go to step 12. 12 Check the inverter solenoid assembly for connection. Is the above motor connected properly? Replace the inverter solenoid assembly. Go to “Inverter solenoid assembly removal”. Replace the connection. 13 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the ADF controller card assembly. Go to “ADF controller card assembly removal”. Go to step 14. 14 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the RIP card assembly. Go to “RIP card assembly removal”. Problem solved.

← Xem tất cả mã lỗi Lexmark X864

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie