Code: 842.00 ... 842.02
Description: 842.00 No response 842.01 HW Protocol 842.02 Logical protocol
Remedy: 1 POR the device. Did the error re-occur? Go to step 2. Problem resolved 2 Check all the connections from the ICC card to the ADF relay card and RIP board to ICC card. Also check the CCD cables for proper connectivity. Are the cables properly connected? Go to step 3 Go to step 4. 3 Properly connect all the cables. Did this fix the issue? Problem resolved Go to step 4. 4 Check the cables for continuity. Is there continuity? Go to Step 6. Go to step 5. 5 Replace the faulty cable. Did this fix the issue? Problem resolved Go to step 6. 6 Is the CCD LED illuminating and not moving when a scan command is given? Replace the CCD. Go to step 7. 7 Replace the ICC card. Did this fix the issue? Problem resolved Go to step 8. 8 Replace the ADF relay card. Did this fix the issue? Problem resolved Go to step 9. 9 Replace the RIP board. Did this fix the issue? Problem resolved Contact your second level support.