Code: 950.xx
Description: Service NCVRAM Mismatch Note: A new controller board or operator panel has been installed, and has not been properly prepared for this use. Install a new note. Do not install both the controller board and the operator panel at the same time without a POR in between.
Remedy: 1 Has the OP panel UICC card been replaced recently? Replace the operator panel assembly with a new, and not previously installed, UICC card. See “UICC removal”. Go to step 2. 2 Has the system board been replaced recently? Replace the RIP board with a new, and not previously installed, system board. See “RIP board removal”. Go to step 3. 3 Turn the printer power off for ten or more seconds. Then turn the printer back on (POR the printer). Is the error gone, and can the printer print? Problem solved. Go to step 4. 4 Clear the NVRAM of the printer: 1. Turn the printer power off. 2.With the printer off, press and hold 6, 7 and 8 on the keypad. 3. Turn the printer on. 4.When Restoring Factory Defaults appears, release the buttons. Note: If the printer locks up on the Restoring Factory Defaults, wait two minutes, and then turn the printer power off. After ten seconds or more, turn the printer power back on without holding down any buttons. Does the error message still appear? Go to step 5. Problem solved. 5 Replace the OP panel UICC card. See “UICC removal”. Does the error message still appear? Replace the RIP board. See “RIP board removal”. Problem solved.