Description: Scanner jam Remove all originals from the scanner. Sensor (ADF pre-registration) static jam The system detected that the sensor (ADF preregistration) is on.
Remedy: 1 Check the sensor (ADF pre-registration). Is the feed media path free of media or media fragments? Go to step 2. Remove any media or media fragments. 2 Check the sensor (ADF pre registration) for operation. Perform the sensor (ADF pre registration) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF pre registration. Operate the actuator of the sensor (ADF pre registration). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 4. Go to step 3. 3 Check the sensor (ADF pre-registration) for connection. Is the above sensor connected properly? Replace the sensor (ADF pre-registration). Go to “Sensor (ADF preregistration)”. Replace the connection. 4 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the ADF controller card assembly. Go to “ADF controller card assembly removal”. Go to step 5. 5 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the RIP card assembly. Go to “RIP card assembly removal”. Problem solved.