Description: Service scanner failure CCD initialization (lamp on) failure The CCD does not make a correct output when it receives a specified amount of light.
Remedy: 1 Check the exposure lamp for operation. Perform the exposure lamp test. 1. Enter the Diagnostics Menu. 2. Touch MOTOR TESTS. 3. Touch Scanner Motor Tests. 4. Touch Exposure lamp. Does the exposure lamp operate properly? Go to step 6. Go to step 3. 2 Check the exposure lamp for connection. Is the above component connected properly? Replace the exposure lamp. Go to “Exposure lamp removal”. Replace the connection. 3 Check the exposure lamp PS card assembly. Is the above card properly connected to the scanner controller card assembly? Replace the exposure lamp PS card assembly. Go to “Exposure lamp PS card assembly removal”. Replace the connection. 4 Check the scanner PS card assembly for connection. Is the above card connected properly? Replace the scanner PS card assembly. Go to “Scanner PS card assembly removal”. Replace the connection. 5 Perform a POR. Does the error remain when the power is turned off/on? Replace the scanner controller card assembly. Go to “Scanner controller card assembly removal”. Problem solved.