Mã lỗi 846.10 — Lexmark X940e

Code: 846.10

Description: Service scanner failure Sensor (ADF width APS X) failure The combinations of outputs from the sensor (ADF width APS 1), sensor (ADF width APS 2) and sensor (ADF width APS 3) are abnormal.
Remedy: 1 Check the sensor (ADF width APS 1) for operation. Perform the sensor (ADF width APS 1) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF width APS 1. Operate the actuator of the sensor (ADF width APS 1). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 2. Go to step 3. 2 Check the sensor (ADF width APS 1) for connection. Is the above sensor connected properly? Replace the sensor (ADF width APS 1). Go to “Sensor (ADF width APS 1)”. Replace the connection. 3 Check the sensor (ADF width APS 2) for operation. Perform the sensor (ADF width APS 2) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF width APS 2. Operate the actuator of the sensor (ADF width APS 2). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 6. Go to step 5. 4 Check the sensor (ADF width APS 2) for connection. Is the above sensor connected properly? Replace the sensor (ADF width APS 2). Go to “Sensor (ADF width APS 2)”. Replace the connection. 5 Check the sensor (ADF width APS 3) for operation. Perform the sensor (ADF width APS 3) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SCANNER TESTS. 3. Touch Sensor Tests. 4. Touch ADF width APS 3. Operate the actuator of the sensor (ADF width APS 3). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 8. Go to step 7. 6 Check the sensor (ADF width APS 3) for connection. Is the above sensor connected properly? Replace the sensor (ADF width APS 3). Go to “Sensor (ADF width APS 3)”. Replace the connection. 7 Place an undamaged document in the ADF, and perform a ADF test. Does the error remain? Replace the ADF controller card assembly. Go to “ADF controller card assembly removal”. Go to step 8.

← Xem tất cả mã lỗi Lexmark X940e

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie