Description: Service engine error Waste toner full error After the sensor (waste toner full) turned on, the pixel count exceed the specified value.
Remedy: 1 Reinstall the waste toner cartridge. Does the error remain? Replace the waste toner cartridge. Go to step 2. Problem solved. 2 Check the sensor (waste toner full) for proper operation. 1. Enter the Diagnostics Menu. 2. Touch BASE SENSOR TEST. 3. Touch Devices. 4. Touch Waste toner cartridge full. Does the display on the operator panel, change every time the sensing area of the above sensor is interrupted or blocked? Go to step 4. Go to step 3. 3 Check the sensor (waste toner full) for proper connection. Is the above component properly connected? Replace the sensor (waste toner full). Replace the connection. 4 Perform a POR. Does the error occur when the power is turned off/on? Replace the lower printer engine card assembly. Go to “Lower printer engine card assembly removal”. Problem solved.