Description: Service MPF failure MPF Tray 5 size sensing error The MPF size width sensor has failed.
Remedy: 1 Perform a POR. Does the error occur when the power is turned off/on? Go to step 2. Problem solved. 2 Check the MPF feed unit assembly. Is the above component properly connected? Replace the MPF feed unit assembly. Go to “MPF feed unit assembly removal”. Replace the connection. 3 Perform a POR. Does the error continue when the power is turned off/on? Replace the upper printer engine card assembly. Go to “Upper printer engine card assembly removal”. Problem solved.