Description: Service engine error Fuser cooling fan lock error When the Fuser cooling fan was operating, fan lock was detected for more than 30 seconds.
Remedy: 1 Perform a POR. Does the error occur when the power is turned off/on? Go to step 2. Perform several print tests. If the problem remains, go to step 2. 2 Check the fuser cooling fan for proper operation. Caution: When performing motor tests, ensure that all cover and door interlock switches are overridden. 1. Enter the Diagnostics Menu. 2. Touch MOTOR TESTS. 3. Touch Fuser cooling fan. Does the above component operate properly? Go to step 4. Go to step 3. 3 Check the fuser cooling fan for proper connection. Is the above component properly connected? Replace the fuser cooling fan. Go to “Fuser cooling fan removal” Replace the connection. 4 Perform a POR. Does the error occur when the power is turned off/on? Replace the lower printer engine card assembly. Go to “Lower printer engine card assembly removal”. Problem solved.