Mã lỗi 842.12 — Lexmark X952

Code: 842.12

Description: Service scanner failure Scanner unit assembly communication failure Communication failure occurred between the scanner controller card assembly and the RIP card assembly.
Remedy: 1 Check all connections of the scanner controller card assembly. Are the connections of the scanner controller card assembly connected properly? Go to step 2. Replace all connections. 2 Check all connections of the ADF controller PCBA. Are the connections of the ADF controller card assembly connected properly? Go to step 3. Replace all connections. 3 Perform a POR. Does the error remain when the power is turned off/on? Replace the ADF controller PCBA. Go to “ADF controller PCBA removal”. Problem resolved 4 Perform a POR. Does the error remain when the power is turned off/on? Replace the scanner controller PCBA. Go to “Scanner controller PCBA removal”. Problem resolved