Mã lỗi 843.20 — Lexmark X952

Code: 843.20

Description: Service scanner failure Scanner unit assembly connection failure There is an open circuit in the scanner interface cable assembly between the scanner controller card assembly and the RIP card assembly.
Remedy: 1 Check the connection of each ADF controller card assembly connector. Is each connector of ADF controller card assembly connected properly? Go to step 2. Connect each connector of ADF controller card assembly properly. 2 Check the connection of each RIP card assembly connector. Are the connectors of the RIP card assembly connected properly? Go to step 3. Connect each connector of the RIP card assembly properly. 3 Perform a POR. Does the error remain when the power is turned off/on? Replace the ADF controller PCBA. Go to “ADF controller PCBA removal”. Problem resolved