Description: Service scanner failure Scanner communication failure Controller detected a communication failure. Communication timeout.
Remedy: 1 Check the scanner interface cable assembly connection between the RIP card assembly and the scanner unit assembly. Is the scanner interface cable assembly connected properly? Go to step 2. Replace the connection. 2 Check all connections of the scanner controller PCBA. Are the connections of the scanner controller card assembly connected properly? Go to step 3. Connect each connector of the scanner controller card assembly properly. 3 Perform a POR. Does the error remain when the power is turned off/on? Replace the scanner controller PCBA. Go to “Scanner controller PCBA removal”. Go to step 4. Problem resolved 4 Perform a POR. Does the error remain when the power is turned off/on again? Replace the RIP PCBA. Go to “RIP PCBA removal”. Problem resolved