Code: 846.13

Description: Service scanner error Switch (platen interlock) open The system detected that the switch (platen interlock) is open.
Remedy: 1 Check the ADF for opening and closing. Does the ADF lay completely flush on the scanner unit when it is in its closed position? Go to step 2. Inspect and adjust the ADF left hinge and right hinge as required. 2 Check the sensor (ADF angle) for proper installation. Is the sensor (FB angle) installed correctly? Go to step 3. Reinstall the sensor (ADF angle). 3 Check the sensor (ADF angle) for operation. Perform the sensor (ADF angle) test. 1. Enter the Diagnostics Menu. 2. Touch SENSOR TESTS. 3. Touch ADF/SCANNER. 4. Touch Sensor (ADF angle). Open and close the ADF unit assembly. Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 5. Go to step 4. 4 Check the sensor (ADF angle) for connection. Is the above sensor connected properly? Replace the sensor (ADF angle). Go to “Sensor (ADF angle) removal”. Replace the connection. 5 Place an undamaged document in the ADF, and perform an ADF test. Does the error remain? Replace the scanner controller card assembly. Go to “Scanner controller PCBA removal”. Go to step 6.