Code: 844.01
Description: Service scanner failure White reference/exposure lamp Illumination failure The large platen glass is not properly installed or missing. The white reference initialization of the scanner unit assembly has failed after a POR or the amount of light from the exposure lamp is inadequate at the start of the scan.
Remedy: 1 Check the large platen glass. Is the large platen glass installed properly? Go to step 2. Remove and clean the large platen glass. Go to “Large platen glass removal”. Reinstall the large platen glass properly. Go to step 3. 2 Remove the large platen glass. Check the bottom of the large platen glass in the vicinity the white reference strip for contamination. Is the vicinity of white reference strip contaminated? Clean the bottom of the large platen glass in the vicinity of the white reference strip. Reinstall the large platen glass properly. Go to step 3. Go to step 4. 3 Perform a POR. Does the error remain? Go to step 4. Problem resolved 4 Check the exposure lamp for connection. Is the above component connected properly? Replace the exposure lamp. Go to “LED exposure bar removal”. Replace the connection. 5 Perform a POR. Does the error continue when the power is turned off/on? Replace the scanner controller PCBA. Go to “Scanner controller PCBA removal”. Problem resolved