Code: 846.10
Description: Service scanner failure Sensor (ADF scan width [x]) failure The combinations of outputs from the sensor (ADF scan width 1), sensor (ADF scan width 2) and sensor (ADF scan width 3) are abnormal.
Remedy: 1 Check the sensor (ADF scan width 1) for operation. Perform the sensor (ADF scan width 1) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SENSOR TESTS. 3. Touch ADF/SCANNER TESTS. 4. Touch Sensor(ADF scan width 1). Operate the actuator of the sensor (ADF scan width 1). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 3. Go to step 2. 2 Check the sensor (ADF scan width 1) for connection. Is the above sensor connected properly? Replace the sensor (ADF scan width 1). Go to “Sensor (ADF scan width 1) removal”. Replace the connection. 3 Check the sensor (ADF scan width 2) for operation. Perform the sensor (ADF scan width 2) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SENSOR TESTS. 3. Touch ADF/SCANNER TESTS. 4. Touch Sensor(ADF scan width 2). Operate the actuator of the sensor (ADF scan width 2). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 5. Go to step 4. 4 Check the sensor (ADF scan width 2) for connection. Is the above sensor connected properly? Replace the sensor (ADF scan width 2). Go to “Sensor (ADF scan width 2) removal”. Replace the connection. 5 Check the sensor (ADF scan width 3) for operation. Perform the sensor (ADF scan width 3) test. Open the ADF left cover assembly. 1. Enter the Diagnostics Menu. 2. Touch SENSOR TESTS. 3. Touch ADF/SCANNER TESTS. 4. Touch Sensor(ADF scan width 3). Operate the actuator of the sensor (ADF scan width 3). Does the display on the operator panel change every time the sensing area of the above sensor is blocked? Go to step 7. Go to step 6. 6 Check the sensor (ADF scan width 3) for connection. Is the above sensor connected properly? Replace the sensor (ADF scan width 3). Go to “Sensor (ADF scan width 3) removal”. Replace the connection. 7 Place an undamaged document in the ADF, and perform an ADF test. Does the error remain? Replace the ADF controller card assembly. Go to “ADF controller PCBA removal”. Go to step 8.