Description: Service system board error RIP card assembly cooling fan failure The RIP card assembly cooling fan is not functioning properly.
Remedy: 1 Perform a POR. Does the error occur when the power is turned off/on? Go to step 2. Perform several print tests. If the problem remains, then go to step 2. 2 Turn the printer off for 60 seconds. Does the error occur when the power is turned off/on again? Go to step 3. Problem solved. 3 Check the RIP card assembly cooling fan and heatsink attachment. Is the above fan attached properly? Replace the RIP PCBA. Go to “RIP PCBA removal”. Reattach the RIP card assembly cooling fan and heatsink.