Description: 649.80 The motor (redrive) did not turn on. 649.81 The motor (redrive) did not turn off. 649.82 The motor (redrive) speed did not ramp up to the required level. 649.83 The motor (redrive) stalled. 649.84 The motor (redrive) ran too slow. 649.85 The motor (redrive) ran too fast. 649.86 The motor (redrive) did not run at the correct timing.
Remedy: Step 1 Reset the printer. Does the problem remain? Go to step 2. The problem is solved. Step 2 Check the cable on the motor (output) and on the JOUTDC connector on the controller board for proper connection and damage, and replace if necessary. Does the problem remain? Go to step 3. The problem is solved. Step 3 Reset the printer. Does the problem remain? Go to step 4. The problem is solved. Step 4 Replace the motor. See “Motor (output) removal”. Does the problem remain? Go to step 5. The problem is solved. Step 5 Reset the printer. Does the problem remain? Go to step 6. The problem is solved. Step 6 Replace the controller board. See “Controller board removal”. Does the problem remain? Contact the next level of support. The problem is solved.