Code: 137.80...137.85
Description: 137.80 The motor (CMY developers) did not turn on. 137.81 The motor (CMY developers) did not turn off. 137.82 The motor (CMY developers) speed did not ramp up to the required level. 137.83 The motor (CMY developers) stalled. 137.84 The motor (CMY developers) ran too slow. 137.85 The motor (CMY developers) ran too fast.
Remedy: Step 1 Reset the printer. Does the problem remain? Go to step 2. The problem is solved. Step 2 Check the CMY developer units for damage and life expiration. Are the developer units damaged or have they reached end of life? Go to step 3. Go to step 4. Step 3 Replace the affected developer unit. See “Developer unit and photoconductor unit removal”. Does the problem remain? Go to step 4. The problem is solved. Step 4 a Remove the CMY developer units, and then manually turn the developer drive gears. b Check the movement of the gears. Do the developer drive gears properly turn? Go to step 6. Go to step 5. Step 5 Replace the affected developer unit. See “Developer unit and photoconductor unit removal”. Does the problem remain? Go to step 6. The problem is solved. Step 6 Check the controller board socket JMAG1 connection. Is the cable properly connected? Go to step 8. Go to step 7. Step 7 Reseat the cable. Does the problem remain? Go to step 8. The problem is solved. Step 8 Check the motor (CMY developers) connection. Is the motor properly connected? Go to step 10. Go to step 9. Step 9 Reseat the cable. Does the problem remain? Go to step 10. The problem is solved. Step 10 Check the motor (CMY developers) cable for damage. Is the cable free of damage? Go to step 12. Go to step 11. Step 11 Replace the cable. Does the problem remain? Go to step 12. The problem is solved. Step 12 Reset the printer. Does the problem remain? Go to step 13. The problem is solved. Step 13 Replace the EP/developer/toner add gearbox. See “EP, developer, toner add gearbox removal”. Does the problem remain? Go to step 14. The problem is solved. Step 14 Reset the printer. Does the problem remain? Go to step 15. The problem is solved. Step 15 Replace the controller board. See “Controller board removal”. Does the problem remain? Contact the next level of support. The problem is solved.