Mã lỗi 420.11 — Lexmark XC8160dtfe

Code: 420.11

Description: The media, with the leading edge on the upper exit area, remains detected by sensor (staple finisher transport) during warm.up sequence.
Remedy: Step 1 a Clear the paper path of any jams or obstructions. b Check if the jam access door is properly closed. c Reset the printer, and then reseat the finisher. Does the problem remain? Go to step 2. The problem is solved. Step 2 Check the staple finisher jam access door for proper installation and damage. Is the door properly installed and free of damage? Go to step 4. Go to step 3. Step 3 Reinstall or replace the door. See “Staple finisher jam access door removal”. Does the problem remain? Go to step 4. The problem is solved. Step 4 Check the staple finisher upper paper guide for proper installation and damage. Is the paper guide properly installed and free of damage? Go to step 6. Go to step 5. Step 5 Reinstall or replace the paper guide. See “Staple finisher aligner paddle and upper paper guide removal”. Does the problem remain? Go to step 6. The problem is solved. Step 6 a Move the tampers from the side to the center, and then clear the area of any obstructions. b Check the tampers for proper installation and damage. Are the tampers properly installed and free of damage? Go to step 8. Go to step 7. Step 7 Reinstall or replace the tampers. See “Staple finisher tamper removal”. Does the problem remain? Go to step 8. The problem is solved. Step 8 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Motor tests b Find the motor (Transport), and then touch Start. Does the motor run? Go to step 11. Go to step 9. Step 9 Check the motor (staple finisher transport) for proper installation and damage. Make sure to reseat the motor connector on both ends. Is the motor properly installed and free of damage? Go to step 11. Go to step 10. Step 10 Reinstall or replace the motor. See “Motor (staple finisher transport) removal”. Does the problem remain? Go to step 11. The problem is solved. Step 11 Check the cables for cuts or damage, and replace if necessary. Does the problem remain? Go to step 12. The problem is solved. Step 12 Check the staple finisher transport gears for proper installation and damage. Are the gears properly installed and free of damage? Go to step 14. Go to step 13. Step 13 Reinstall or replace the gears. See “Staple finisher transport gears removal”. Does the problem remain? Go to step 14. The problem is solved. Step 14 Check the compiler feed roller for proper installation and damage. Manually turn the roller and make sure that the compiler feed idler rolls with the roller. Is the roller properly installed and free of damage? Go to step 16. Go to step 15. Step 15 Reinstall or replace the roller. See “Staple finisher compiler feed roller removal”. Does the problem remain? Go to step 16. The problem is solved. Step 16 Check the compiler feed idler for proper installation and damage. Manually turn the mating roller and make sure that the idler rolls with the roller. Is the idler properly installed and free of damage? Go to step 18. Go to step 17. Step 17 Reinstall or replace the idler. See “Staple finisher compiler feed idler removal”. Does the problem remain? Go to step 18. The problem is solved. Step 18 Check the staple finisher aligner paddle for proper installation and wear or damage. Make sure to manually turn the paddle to check for proper operation. Is the paddle properly installed and free of damage? Go to step 20. Go to step 19. Step 19 Reinstall or replace the paddle. See “Staple finisher aligner paddle and upper paper guide removal”. Does the problem remain? Go to step 20. The problem is solved. Step 20 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Motor tests b Find the motor (Aligner paddle), and then touch Start. Does the motor run? Go to step 23. Go to step 21. Step 21 Check the motor for proper installation and damage. Make sure to reseat the motor connector on both ends. Is the motor properly installed and free of damage? Go to step 23. Go to step 22. Step 22 Reinstall or replace the motor. See “Motor (staple finisher aligner paddle) removal ”. Does the problem remain? Go to step 23. The problem is solved. Step 23 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Sensor tests > Staple Finisher > Compile and staple section b Find the sensor (Aligner paddle). Does the sensor status change while toggling the sensor? Go to step 26. Go to step 24. Step 24 Check the sensor for proper installation and damage, and replace if necessary. Make sure to reseat the sensor connector on both ends. Is the sensor properly installed and free of damage? Go to step 26. Go to step 25. Step 25 Reinstall or replace the sensor. See “Staple finisher aligner paddle gears removal”. Does the problem remain? Go to step 26. The problem is resolved. Step 26 a Check the staple finisher aligner paddle gears for damage, and replace if necessary. See “Staple finisher aligner paddle gears removal”. b Check the gears for proper alignment and installation. c Check the actuator for damage, and replace if necessary. Does the problem remain? Go to step 27. The problem is resolved. Step 27 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Motor tests b Find the motor (Upper exit), and then touch Start. Does the motor run? Go to step 30. Go to step 28. Step 28 Check the motor for proper installation and damage. Is the motor properly installed and free of damage? Go to step 30. Go to step 29. Step 29 Reinstall or replace the motor. See “Motor (staple finisher upper exit roller) removal”. Does the problem remain? Go to step 30. The problem is solved. Step 30 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Sensor tests > Staple Finisher > Transport and exit section b Find the sensor (Upper exit roller). Does the sensor status change while toggling the sensor? Go to step 33. Go to step 31. Step 31 Check the sensor for proper installation and damage. Make sure to reseat the sensor connector on both ends. Is the sensor properly installed and free of damage? Go to step 33. Go to step 32. Step 32 Reinstall or replace the sensor. See “Sensor (staple finisher upper exit roller) removal”. Does the problem remain? Go to step 33. The problem is solved. Step 33 a Check the staple finisher front upper exit roller position gears for proper installation and damage, and replace if necessary. See “Staple finisher front upper position exit roller gears removal”. b Check the actuator and lever for proper installation and damage, and replace if necessary. c Make sure that the springs are properly installed. d Check if the roller goes up and down after moving the gears. e Lift the gear to check if the actuator covers the sensor. Does the problem remain? Go to step 34. The problem is solved. Step 34 a Check the staple finisher rear upper exit roller position gears and lever for proper installation and damage, and replace if necessary. See “Staple finisher rear upper position exit roller gears removal”. b Check if the roller goes up and down after moving the gears. Does the problem remain? Go to step 35. The problem is solved. Step 35 a Check the staple finisher upper exit roller for proper installation and damage, and replace if necessary. See “Staple finisher upper exit roller removal”. b Check if the roller goes up and down after moving the gears. Does the problem remain? Go to step 36. The problem is solved. Step 36 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Motor tests b Find the motor (Exit), and then touch Start. Does the motor run? Go to step 39. Go to step 37. Step 37 Check the motor for proper installation and damage. Is the motor properly installed and free of damage? Go to step 39. Go to step 38. Step 38 Reinstall or replace the motor. See “Motor (staple finisher exit) removal”. Does the problem remain? Go to step 39. The problem is solved. Step 39 Check the exit gears for proper alignment and installation. Are the gears properly aligned or installed? Go to step 41. Go to step 40. Step 40 Realign or reinstall the exit gears. Does the problem remain? Go to step 41. The problem is solved. Step 41 Check the exit gears for damage. Are the gears free of damage? Go to step 43. Go to step 42. Step 42 Replace the gears. See “Staple finisher exit gears removal”. Does the problem remain? Go to step 43. The problem is solved. Step 43 Check the exit roller belts for proper installation and damage. Are the belts properly installed or free of damage? Go to step 45. Go to step 44. Step 44 Reinstall or replace the belts. See “Staple finisher exit roller belts removal”. Does the problem remain? Go to step 45. The problem is solved. Step 45 Reseat all cable connectors in the staple finisher controller board, and then reset the printer. Does the problem remain? Go to step 46. The problem is solved. Step 46 Replace the controller board. See “Staple finisher controller board removal”. Does the problem remain? Contact the next level of support. The problem is solved.

← Xem tất cả mã lỗi Lexmark XC8160dtfe

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie