Code: 31.80...31.85
Description: 31.80 Fuser smart chip error 31.81 Fuser I2C packet time-out 31.82 Fuser I2C packet has been sent but code timed out on receiving the data (callback) 31.83 Fuser security error in the send challenge sequence 31.84 Fuser ROM signature error 31.85 Fuser smart chip stuck or busy; status register and/or CRI Arbiter register report busy)
Remedy: Step 1 Ensure that the fuser is installed properly. Is the fuser properly installed? Go to step 2. Reinstall the fuser properly.
Step 2 Remove the fuser and install a different fuser. Does the error remain? Go to step 3. Problem resolved.
Step 3 Ensure the cable for socket "J27" on the controller board is properly connected. Is the above component properly connected? Go to step 4. Reseat the connection or replace the cable. Go to step 4.
Step 4 Reset the machine. Does the error continue? Replace the controller board. Go to “Controller board removal”. Problem resolved.
Step 2 Remove the fuser and install a different fuser. Does the error remain? Go to step 3. Problem resolved.
Step 3 Ensure the cable for socket "J27" on the controller board is properly connected. Is the above component properly connected? Go to step 4. Reseat the connection or replace the cable. Go to step 4.
Step 4 Reset the machine. Does the error continue? Replace the controller board. Go to “Controller board removal”. Problem resolved.