Code: 174.03...175.07
Description: 174.03 HVPS cooling fan took too long to ramp up 174.04 HVPS cooling fan under speed or stalled during speed adjustment state 174.05 HVPS cooling fan over speed during speed adjustment state 174.06 HVPS cooling fan capture data is invalid and speed control is at maximum in fan control idle state 174.07 HVPS cooling fan capture data is invalid and speed control is at maximum in fan control adjustment state 175.03 Miscellaneous cooling fan took too long to ramp up175.04 Miscellaneous cooling fan under speed or stalled during speed adjustment state 175.05 Miscellaneous cooling fan over speed during speed adjustment state 175.06 Miscellaneous cooling fan capture data is invalid and speed control is at maximum in fan control idle state 175.07 Miscellaneous cooling fan capture data is invalid and speed control is at maximum in fan control adjustment state
Remedy: Step 1 Ensure the miscellaneous cooling fan cable is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connection.
Step 2 Reset the machine. Does the error continue? Replace the HVPS fan with cable. Go to step 3. Problem resolved.
Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
Step 2 Reset the machine. Does the error continue? Replace the HVPS fan with cable. Go to step 3. Problem resolved.
Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.