Code: 1040
Description: Overcurrent detection of lower cassette base motor (The second paper feeder)
• Excessive current has flowed through the lower cassette base motor which elevates the bottom plate in the cassette when the lower cassette is installed in the second paper feeder PF-30A or power is turned on.
• Excessive current has flowed through the lower cassette base motor which elevates the bottom plate in the cassette when the lower cassette is installed in the second paper feeder PF-30A or power is turned on.
Causes: Defective lower cassette base motor. Defective bottom plate elevation mechanism of lower cassette. Defective main board of paper feeder PF-30A. Defective engine controller PWB (KP-801).
Remedy: Defective lower cassette base motor. Replace the lower cassette base motor. See paper feeder PF-30A’s service manual.
Defective bottom plate elevation mechanism of lower cassette. Check whether there is an object that prevents the bottom plate of lower cassette from operating normally.
Defective main board of paper feeder PF-30A. Replace the main board of paper feeder PF-30A. See paper feeder PF-30A’s service manual.
Defective engine controller PWB (KP-801). Replace the engine controller PWB (KP- 801).
Defective bottom plate elevation mechanism of lower cassette. Check whether there is an object that prevents the bottom plate of lower cassette from operating normally.
Defective main board of paper feeder PF-30A. Replace the main board of paper feeder PF-30A. See paper feeder PF-30A’s service manual.
Defective engine controller PWB (KP-801). Replace the engine controller PWB (KP- 801).