Code: 1050
Description: Overcurrent detection of upper cassette base motor (The third paper feeder)
• Excessive current has flowed through the upper cassette base motor which elevates the bottom plate in the cassette when the upper cassette is installed in the third paper feeder PF- 30A or power is turned on.
• Excessive current has flowed through the upper cassette base motor which elevates the bottom plate in the cassette when the upper cassette is installed in the third paper feeder PF- 30A or power is turned on.
Causes: Defective upper cassette base motor. Defective bottom plate elevation mechanism of upper cassette. Defective main board of paper feeder PF-30A. Defective engine controller PWB (KP-801).
Remedy: Defective upper cassette base motor. Replace the upper cassette base motor. See paper feeder PF-30A’s service manual.
Defective bottom plate elevation mechanism of upper cassette. Check whether there is an object that prevents the bottom plate of upper cassette from operating normally.
Defective main board of paper feeder PF-30A. Replace the main board of paper feeder PF-30A. See paper feeder PF-30A’s service manual.
Defective engine controller PWB (KP-801). Replace the engine controller PWB (KP- 801).
Defective bottom plate elevation mechanism of upper cassette. Check whether there is an object that prevents the bottom plate of upper cassette from operating normally.
Defective main board of paper feeder PF-30A. Replace the main board of paper feeder PF-30A. See paper feeder PF-30A’s service manual.