Code: 2000
Description: Main drive motor lock
• The frequency generation pulse which the main drive motor generates to CPU (U2) on the engine controller PWB (KP-801) in normal operation (after self-diagnostics codes 2010 and 2020 are cleared) is not at the correct frequency.8
• The frequency generation pulse which the main drive motor generates to CPU (U2) on the engine controller PWB (KP-801) in normal operation (after self-diagnostics codes 2010 and 2020 are cleared) is not at the correct frequency.8
Causes: Defective main drive motor. Excessive torque for driving drum unit or primary transfer unit. (Overloaded by a damaged gear.) Defective harness (S02571) between engine controller PWB (KP-801) and main drive motor, or poor contact of the connector terminals. Defective engine controller PWB (KP-801).
Remedy: Defective main drive motor. Replace the main drive motor.
Excessive torque for driving drum unit or primary transfer unit. (Overloaded by a damaged gear.) Check if the drum unit or primary transfer unit rotates smoothly. Check for broken gears. Replace if any.
Defective harness (S02571) between engine controller PWB (KP-801) and main drive motor, or poor contact of the connector terminals. Check the continuity of the harness (S02571). Check the insertion of connectors.
Defective engine controller PWB (KP-801). Replace the engine controller PWB (KP- 801).
Excessive torque for driving drum unit or primary transfer unit. (Overloaded by a damaged gear.) Check if the drum unit or primary transfer unit rotates smoothly. Check for broken gears. Replace if any.
Defective harness (S02571) between engine controller PWB (KP-801) and main drive motor, or poor contact of the connector terminals. Check the continuity of the harness (S02571). Check the insertion of connectors.
Defective engine controller PWB (KP-801). Replace the engine controller PWB (KP- 801).