Mã lỗi 6000 — Kyocera FS8100DN

Code: 6000

Description: Fuser heater 1/2 break
Fuser thermistor 1 detected less than 75 °C/167 °F for 30 s during worming up. Fuser thermistor 1 deduced 40 °C/104 °F or more for 5 s during worming up. Fuser thermistor 3 deduced less than 90 °C/194 °F for 30 s during worming up. Fuser thermistor 3 deduced less than 160 °C/320 °F for 90 s during worming up. Fuser thermistor 3 deduced less than 140 °C/284 °F for 5 s during stand-by.
Causes: Defective fuser heater 1/2. Defective fuser thermostat 1. Installation defectiveness on fuser thermistor 1/2. Defective PWB.
Remedy: Defective fuser heater 1/2. Check for continuity across each heater. If none, replace the fuser unit.
Defective fuser thermostat 1. Check for continuity across thermostat. If none, remove the cause and replace the fuser unit.
Installation defectiveness on fuser thermistor 1/2. Measure the resistance. If it is ∞, replace the fuser unit.
Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.