Code: 7220
Description: Broken internal thermistor 2 wire
An abnormal value is detected in the input data to inner temperature sensor 2
An abnormal value is detected in the input data to inner temperature sensor 2
Causes: Poor contact in the connector terminals. Defective engine PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC28 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary.
Defective engine PWB. Replace the engine PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.