Code: 7913
Description: Developing unit M EEPROM error
Reading from or writing to EEPROM cannot be performed.
Reading from or writing to EEPROM cannot be performed.
Causes: Poor contact in the connector terminals. Defective developing PWB M.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC17 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary.
Defective developing PWB M. Replace the developing unit M.
Defective developing PWB M. Replace the developing unit M.