Code: 4010
Description: Polygon motor steady-state problem
• When high-speed rotation from lowspeed rotation is requested, the motor does not become stable even after 20 s.
• When high-speed rotation from lowspeed rotation is requested, the motor does not become stable even after 20 s.
Causes: Poor contact in the polygon motor connector terminals. Defective polygon motor. Defective power supply unit. Defective power supply from engine controller PWB. Defective engine controller PWB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the LSU. Check if 24 V DC is supplied to YC2-1 on the engine controller PWB. If not, replace the power supply unit. Check if 24 V DC is output from YC8-10 on the engine controller PWB. If not, replace the engine controller PWB. Replace the engine controller PWB.