Code: 6000
Description: Fuser heater brea
Fuser thermistor 1 is detected 40°C/ 104°F below with 10 s continuously during warm-up and ready in.
Fuser thermistor 1 is detected 40°C/ 104°F below with 10 s continuously during warm-up and ready in.
Causes: Defective fuser heater M or S. Installation defectiveness on fuser thermistor 1. Defective fuser thermostat. Defective PWB.
Remedy: Defective fuser heater M or S. Replace the fuser heater M or S. Installation defectiveness on fuser thermistor 1. Check the mounting state of the fuser thermistor 1. If any problem is found, repair it. Defective fuser thermostat. Replace the fuser thermostat. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.