Code: 204
Description: Polygon motor error 3: XSCRDY signal error
The SCRDY_N signal remains HIGH for 200 ms while the LD unit is firing.
The SCRDY_N signal remains HIGH for 200 ms while the LD unit is firing.
Causes: Polygon motor/driver board harness loose or disconnected. Polygon motor/driver board defective. Laser optics unit defective. IPU (EGB) defective 1. Replace the interface harness of the laser optics unit. 2. Replace the laser optics unit. 3. Replace the EGB (Engine Board).