Code: 1200
Description: Side registration motor error
• The duplexer PWB of the optional duplexer cannot detect the home position of the adjust guide.яяяяяяя
• The duplexer PWB of the optional duplexer cannot detect the home position of the adjust guide.яяяяяяя
Causes: Defective duplexer DU-300. Defective engine controller PWB (KP-1054).
Remedy: Defective duplexer DU-300. Refer to the duplexer DU-300's service manual. Defective engine controller PWB (KP-1054). Replace the engine controller PWB (KP- 1054).