Code: 5302
Description: Eraser lamp 2 error (cyan drum unit)
• The eraser lamp 2 [PWB] (KP-976) of the cyan drum unit does not communicate with the engine controller PWB (KP-1054) normally.
• The eraser lamp 2 [PWB] (KP-976) of the cyan drum unit does not communicate with the engine controller PWB (KP-1054) normally.
Causes: Defective eraser lamp 2 [PWB] (KP- 976). Defective engine controller PWB (KP-1054). Defective drum PWB 2 (KP-972). Defective harness between drum PWB 2 (KP-972) and eraser lamp 2 [PWB] (KP-976), or poor contact of the connector terminals. Defective harness (S02869) between engine controller PWB (KP-1054) and LED print heads relay PWB (KP-1048), or poor contact of the connector terminals. Defective LED print heads relay PWB (KP-1048).
Remedy: Defective eraser lamp 2 [PWB] (KP- 976). Replace the eraser lamp 2 [PWB] (KP-976). Defective engine controller PWB (KP-1054). Replace the engine controller PWB (KP- 1054). Defective drum PWB 2 (KP-972). Replace the cyan drum unit. See page 1-6- 12. Defective harness between drum PWB 2 (KP-972) and eraser lamp 2 [PWB] (KP-976), or poor contact of the connector terminals. Check the connection of the YC401 connector of the drum PWB 2 (KP-972), if there is trouble, remedy or replace. Defective harness (S02869) between engine controller PWB (KP-1054) and LED print heads relay PWB (KP-1048), or poor contact of the connector terminals. Check the continuity of the harness (S02869), check the connection YC3 connector of the engine controller PWB (KP- 1054), if there is trouble, remedy or replace. Defective LED print heads relay PWB (KP-1048). Replace the LED print heads relay PWB (KP-1048).