Code: 7002
Description: Toner motor 2 overcurrent detection error (cyan toner)
• The engine controller PWB (KP-1054) detected the overcurrent of toner motor 2.
• The engine controller PWB (KP-1054) detected the overcurrent of toner motor 2.
Causes: Defective toner motor 2. Defective engine controller PWB (KP-1054). Lump of toner inside cyan toner container or defectiveness of toner replenishment drive system.
Remedy: Defective toner motor 2. Replace the toner motor 2. See page 1-6- 34. Defective engine controller PWB (KP-1054). Replace the engine controller PWB (KP- 1054). Lump of toner inside cyan toner container or defectiveness of toner replenishment drive system. Replace the cyan toner container.